Key Features
Brand | : | Genesys |
Model | : | Genesys WB |
Origin | : | UK |
Appearance | : | Colourless liquid |
pH as supplied | : | 6.0 - 6.5 |
Specific gravity | : | 1.09 - 1.13 |
Freezing point | : | -2°C |
View More Info |
RO
Antiscalant – Genesys WB
The
Genesys WB RO Antiscalant is a high-efficiency, multi-purpose scale
inhibitor and dispersant specifically developed for reverse osmosis (RO),
nanofiltration (NF), and ultrafiltration (UF) membrane systems operating
with brackish water. Designed to prevent scaling, fouling, and inorganic
precipitation, Genesys WB ensures superior membrane performance,
prolonged system life, and reduced cleaning frequency. Its unique formulation
offers exceptional control of calcium carbonate, calcium sulfate, barium
sulfate, strontium asulfate, calcium fluoride, and metal oxide scales, even
under high-recovery and high-TDS (Total Dissolved Solids) conditions.
Engineered with advanced phosphonate and polymer chemistry, Genesys WB provides reliable protection across a wide range of feed water qualities and operational conditions, making it ideal for industrial, commercial, and municipal ROsystems.
In
reverse osmosis and nanofiltration systems, as water is forced through the
semi-permeable membranes, dissolved salts and minerals concentrate on the feed
side. Without effective scale control, these minerals can crystallize and form
deposits on the membrane surface — a process known as scaling. This
leads to increased differential pressure, reduced permeate flow, and decreased
membrane life.
Genesys
WB Antiscalant
effectively inhibits this scaling by interfering with crystal formation and
growth, keeping scale-forming compounds in a soluble state. It also disperses
colloidal particles and metallic oxides, maintaining membrane surface
cleanliness and permeability.
Formulated
as a liquid antiscalant, Genesys WB is easy to handle, dose, and apply.
It is compatible with all major membrane types and has been approved by leading
membrane manufacturers for its safety and performance consistency.
Chemical Properties and Composition
The
formulation contains a blend of phosphonates, polycarboxylates,
and dispersing polymers that work synergistically to inhibit scaling and
fouling mechanisms. It is free from phosphates, making it environmentally
friendly and compliant with stringent discharge regulations.
Mechanism of Action
The performance of Genesys WB is based on three synergistic mechanisms thatprevent the deposition of scale-forming minerals: Threshold Inhibition:
Together,
these actions protect membranes from scaling and fouling, ensuring consistent
flux, reduced pressure drop, and improved system performance over time.
Applications
Genesys
WB RO Antiscalant
is suitable for a broad range of water treatment applications, particularly in
systems using brackish or moderately saline feed water. Its versatility makes
it ideal for:
Dosage and Feeding Guidelines
The
required dosage of Genesys WB depends on the feed water composition,
recovery rate, and scaling potential. It is usually dosed continuously into the
feed water before the cartridge filter and high-pressure pump.
For
precise dosage, a scaling potential analysis should be conducted, or a
water treatment specialist should be consulted to ensure optimal dosing
conditions.
Key Features and Benefits
Technical Specifications (Typical Values)
·
Form: Liquid
·
pH (Concentrate): 3.0 – 5.0
·
Density: 1.15 – 1.25 g/cm³
·
Solubility: 100% in water
·
Operating pH Range: 5 – 9
· Operating Temperature: 0°C – 60°C· Storage Temperature: 0°C – 3
C
·
Shelf Life: Minimum 2 years from manufacturing date
·
Packaging: Available in 5L, 25L, 200L, and 1000L
containers
Storage and Handling
Performance and Quality Assurance
Each
batch of Genesys WB undergoes stringent quality control testing to
ensure chemical purity, stability, and consistent performance. It is approved
by major RO membrane manufacturers and conforms to international standards for
water treatment chemicals.
Continuous
use of Genesys WB has been proven to:
This
reliability has made Genesys WB a preferred antiscalant for brackish water RO plants
around the world.
Conclusion
The
Genesys WB RO Antiscalant is a superior, high-performance solution for
preventing scale and fouling in membrane-based water treatment systems.
Specifically designed for brackish water, it delivers reliable performance
under challenging feed conditions, ensuring long-term membrane protection,
stable operation, and reduced cleaning requirements.
With
its proven efficiency, chemical stability, and environmental safety, Genesys
WB is the ideal choice for industries and municipal plants aiming to
maximize system performance while minimizing operational costs. Its
multi-functional design and compatibility with all major RO membranes make it a
trusted and indispensable additive for achieving clean, consistent, and
cost-effective water purification.
Brand | Genesys |
---|---|
Model | Genesys WB |
Origin | UK |
Appearance | Colourless liquid |
pH as supplied | 6.0 - 6.5 |
Specific gravity | 1.09 - 1.13 |
Freezing point | -2°C |
(0)
Login To Leave Review
EMI Details
T&C